Jobsinghana.com
 

Remote Management System Coordinator

JOB SUMMARY

Company Confidential
Industry Telecommunica...
Category Engineering
Location Accra
Job Status Full-time
Salary GHS
Education HND
Experience 1 year
Job Expires Oct 19, 2022
Contact ...
 

Job Description

PURPOSE OF THE JOB
To manage and ensure 99% RPMS availability on installed sites, 100% acceptance for installed RPMS sites and maintaining RPMS visibility and data quality for all sites.

ESSENTIAL FUNCTIONS AND RESPONSIBILITIES
RPMS Availability:
  • All sites RPMS for all module need to be online. GPRS Modem, All PMM, DPC5, Deepsea, Intrusion detector, Orion or Eltek.
  • GT Modem GPRS Signal need to be in between -60 dBM TO -30 dBM range.
  • GT Temperature probe need to work to every site
  • PMM Power factor for all three line need to .9 to 1.
  • PMM CT need to show correct load current for ECG and each Tenant on L1, L2 and L3.
  • DPC5 DC CT need to be show correct load current for all Tenant.
  • Intrusion detector must work where it is installed.
  • Deepsea need to show DGHRS for all sites and Fuel level for all sites where Genset has base tank. Standard configuration for all deep-sea for alarms and Power source.
  • Alarm correction on DC Plants (Orion and Eltek). All Delta and Eltek controller need to show standard parameters.
  • Proactive approach for zero SIT.
  • RPMS Maintenance /PM Audit for hardware life span and data quality.
  • Identify sites without Class A SPD.
  • Alarm need be terminated for Class A SPD on GT AUX 5.
100% acceptance with complete RPMS installation:
  • Team shouldn’t leave the site unless PNOC confirm that they have correct data as site configuration with all module online visibility
  • Clearance of alarm and testing with PNOC
  • Budget preparation for new installation
  • PO, MRO for new module and IDF request (Biasness as usual)
  • Module request for new installation
  • MRO for old module
  • All required documentation for invoicing.

Detail for faulty and replace modules:

  • Make sure team need to write old and new module detail for repair and warranty record. Repair center will not accept faulty module without this detail (Date, Site ID, Site Name, reported fault, Diagnosed fault, new module SR Number and MAC ID). Team need to give this information to P-NOC before leaving the site as well.
  • If module get burnt /faulty due to surge need to make a comprehensive report to share with customer for module replacement.
  • Need to make sure each region has enough repair or fresh module to close site in same day.
  • Track module Serial number to check warranty status.

OTHER DUTIES AND RESPONSIBILITIES

  • Site visit for critical fault and maintenance training for O&M teams
  • Need to prepare report as per requirement
  • Need to request and flow up to get require resources to complete job in time
  • RPMS availability after any change in to Site configuration or Genset Swap.

SUPERVISORY RESPONSIBILITIES

  • Schedule team activities on weekly /Daily bases

GENERAL DUTIES

  • Any other duties that may be assigned.

KEY PERFORMANCE INDICATORS

  • 99% RPMS availability on all sites
  • 100% acceptance for installed RPMS sites
  • 100% visibility and data quality on all sites
  • Well documented detail for faulty and replacement modules
  • Prompt attendance to all customer request and needs
  • Timely resolution of faults and replacement of modules
  • Strict Adherence to health and safety policies and procedures.
  • Regular reporting by shearing tracker for ongoing activity.
  • Management and Monitoring of respective sites & team members.
  • Weekly/daily request and closing of faulty parts replacements as and when needed.
  • Daily, weekly and monthly reports activities
  • Follow up on escalations till closure with SI ensuring g the same site doesn’t fail again in term of RPMS availability.
  • RPMS Preventive Maintenance to be monitored for quality PM.
  • Routine visits to selected sites

Required Skills or Experience

  • HND or degree in Electrical Engineering or its equivalent

EXPERIENCE

  • 1 to 2 years experience in similar role with similar responsibilities.

KNOWLEDGE

  • Good Knowledge of DC system, DC system controller configuration, Genset, Deepsea Configuring, Base tank fuel prob configuration, RPMS Installation, integration, commissioning and maintenance.

SKILLS & ABILITIES

  • Computer literate (Microsoft Windows & Microsoft office).
  • Planning and organizing Skills
  • Leadership skills
  • High degree of Integrity.
  • Fluent in English language
  • Timely, accurate and quality reporting
  • Good communication skills
  • Decision making & Problem solving
  • Initiative, creative & innovative

PERSONAL ATTRIBUTES

  • Team player
  • Customer Focused
  • Ability to work under pressure
  • Ability to multi-task
  • Safety Awareness

How To Apply

Sorry, job has expired.

 
Note

Please note, employers receive numerous applications per posting and will only shortlist the most qualified candidates. Also Jobsinghana.com is not involved in any decision made by an employer/recruiter and therefore does not guarantee that applications sent will result in a candidate being shortlisted/selected for that position.
 
 
To Top